OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00063
PWS Name: WICKIUP WATER DISTRICT
 
Who Was Contacted and Phone: Daryl Gardner (503) 458-6555
Contact Date: 12/05/2006
Contacted By: KARCH, ANDREW (DWP)
Contact Method/Location: Field
 
Assistance Type: CIRCUIT RIDER ASSISTANCE
Reasons: N/A
N/A
 
Details: SUMMARY: Received request from Wickiup WD for assistance with equipment recommendations. DETAILS: The system owns and operates two water treatment plants to treat surface water which supply water to approximately 620 connections with a population of approximately 1702 people. WTP A is a slow sand filter plant rated for 100 gpm. WTP B is a package treatment plant with coagulation, flocculation, sedimentation, and rapid sand filtration rated for 150 gpm. The plant was designed for 175 gpm however the maximum output is 150 gpm due to the poor water quality produced at 175 gpm. Both Plants have post hypo chlorination. Received assistance request from Daryl Gardner, operator for the Wickiup Water District. The existing meter at WTP A following the clearwell does not display instantaneous flow rates. A meter that can display the instantaneous flow rate from the clearwell is needed to perform a TC Study for WTP A. ACTION PERFORMED – Complete research to identify the proper equipment for the needed application. Submitted report with recommendation to district. ACTION NEEDED: None at this time on this issue. Once a flow meter is installed and the maximum flow rate for WTP A can be determined a CT Study will need to be done for WTP A.


More information for this water system: SDWIS ID 3875
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  Corrosion Control (LCR)  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Something missing? The new Chemical Results page replaces many pages, including arsenic and nitrate.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login