OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 91810
PWS Name: FERN RIDGE MIDDLE SCHOOL
 
Who Was Contacted and Phone: Jeff Theissen (541) 935-2253 ext. 216
Contact Date: 11/24/2008
Contacted By: PARRY, BETSY (REGION 2)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY COMPLAINT
Reasons: N/A
None
 
Details: SUMMARY: Received call from Parent about closed school PWS DETAILS: Received a call from a parent of a student at Fern Ridge Middle School, who is investigating several possible environmental exposures of her child in the past few weeks. She asked about the schools water - I told her what I knew about the high pH at the school reported on October 21, 2008, and their use of bottled water while the system was flushed. But she explained that the entire system had been shut down, with portable toilets brought in. I phoned Jeff Theissen, who explained that at the same time as the pH spike, a booster pump had failed, leaving them without water pressure. He shut off the storage tank side of the water system while the pump was replaced. I researched proper protocol for total loss of pressure in a chorinated system, and left Jeff a message detailing the following: A boil water advisory, and notify the state drinnking water program. Once positive pressure has been restored, flush the system, verify the chlorine residual level, take coliform samples, and do not lift the boil water notice until the sample results show absence of coliform bacteria. Then notify users that the water is safe to use after they flush the lines. ACTION NEEDED: Confirm with Jeff what steps he took after restoring pressure to the system.


More information for this water system: SDWIS ID 1033
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login