OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00540
PWS Name: MONROE, CITY OF
 
Who Was Contacted and Phone: Jeff Houchin (541) 451-1117
Contact Date: 06/26/2009
Contacted By: PARMENTER, AMY (REGION 2)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: Disinfection Byproducts
Operations
 
Details: SUMMARY: TTHM RAA Exceedance DETAILS: Monroe exceeded the Running Annual Average MCL for TTHMs taken 6/08, 8/08, 10/08, and 2/09. The system switched from a groundwater source to surface water in 2/09-- however, they believe that groundwater was likely still in the distribution system when the February sample was taken. Another sample was taken in 5/09, this time from surface water, and both TTHM and HAA5 exceeded the MCL. John Potts with the circuit rider program visited the system to conduct a tracer study. He said their raw TOC was high, but it drops with warmer temperatures. The systems chlorine goal in the plant is 1.5 to 2.5 mg/L, but it drops to 0.4 mg/L in the distribution system. The system is attempting to decrease its DBPs by increasing turnover in the reservoir and increasing hydrant flushing from 10/month to one every day. I spoke with Jeff on 6/26 and he is going to issue public notice for TTHM the week of 6/29. Disinfection profiling will not be required until the system exceeds the RAA with four quarters of surface water sampling. ACTION NEEDED: Await copy of public notice. Monroe to reissue public notice every three months as long as violation continues.


More information for this water system: SDWIS ID 3364
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login