Who Was Contacted and Phone: Dan Reitz, Randy Reitz (541) 997-8011
Contact Date: 10/28/2009
Contacted By: POTTS, JOHN (DWP)
Contact Method/Location: Field
 
Assistance Type: CIRCUIT RIDER ASSISTANCE
Reasons: N/A
N/A
 
Details: SUMMARY: Tracer Study Preliminary Visit DETAILS: The Water District has installed a new 60 gpm Westech Altpac membrane WTP. The new plant went on line in December 2008 and DWS-DWP has required a tracer study be conducted to complete the plan review process. I met with Dan to conduct a pre tracer study inspection to verify what equipment was installed chlorine injection system, sample taps, computer tracking/recording capability, storage tank plumbing configuration/effluent meter and pumping systems. Issues that I identified that must be resolved are: complete storage tank replumbing that is partially complete and installation of a low off on Hilltop Dr to create desired demand for the study. These will be completed prior to the study. I also explained how the study was conducted. I called Randy Reitz to discuss computer system, pump information and construction schedule. The distribution pump system has a maximum flow of 60 gpm-- therefore the study will be conducted at that flow. I contacted Casey Lyon, Department of Human Services-DWP and set up an appointment for 11/17/09 to discuss the CT procedure prior to the field study. ACTION NEEDED: Meet with DWP on 11/17/09 than conduct tracer study.


More information for this water system: SDWIS ID 3953
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login