OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00296
PWS Name: FAIRVIEW, CITY OF
 
Who Was Contacted and Phone: Derrick Yates (503) 665-9320
Contact Date: 04/27/2010
Contacted By: NUSRALA, JAMES (REGION 1)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: VOCs
N/A
 
Details: SUMMARY: Response to VOC detects in 2nd Qtr 2010 DETAILS: Derrick called regarding detections of Tetrachloroethylene (PCE)-4.32 micrograms per liter (ppb) and Trichloroethylene (TCE)-0.56 ppb, below the respective MCLs at well #6. I indicated that MCL compliance determined by running annual average of last 4 quarters of monitoring data for each chemical. Based on my calculations running annual average was 4.78 ppb for PCE, and 0.59 ppb for TCE (MCL is 5 ppb, 5.49 for compliance for both chemicals). Derrick noted well # 6 has been turned off since Dec 2008, and city not planning on using well #6 this summer. I indicated that tier 2 public notice and treatment would be required if City uses well, and the running annual average is greater than the MCL for either of these chemicals. ACTION NEEDED: Derrick to consult internally with City to determine plans to finish well #9, so that it may be used to meet high summer demand. Well #6 continues to be off-line, City will consult with DWP prior to any considered use of well. City to continue quarterly monitoring of PCE, TCE, and Ethylene Dibromide at well #6 to keep eye on levels. I indicated that if levels are reliably and consistently below the MCL, frequency can be reduced to annually (would apply to TCE - as its below MCL). City to stay on quarterly for all three for now, and will let me know if wish to drop TCE to annually.
 
Associated Alerts: CHEM4051 - 04/29/2010 - TETRACHLOROETHYLENE , TRICHLOROETHYLENE

CHEM4051 - 04/29/2010 - TETRACHLOROETHYLENE , TRICHLOROETHYLENE



More information for this water system: SDWIS ID 3298
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login