Who Was Contacted and Phone: Al Kitzman (541) 766-6018
Contact Date: 07/05/2011
Contacted By: PARMENTER, AMY (REGION 2)
Contact Method/Location: Office
 
Assistance Type: OTHER REGULATORY - OTHER
Reasons: SWTR
None
 
Details: SUMMARY: Turbidity 95% violation DETAILS: Fort Hoskins Park exceeded 5% of the daily turbidity readings for the month of May and received a violation. I spoke with Al Kitzman on 7/5/11 who said that the unused line to the abadoned Fort Tavern had damaged during a freeze and was losing water which drew down the holding tank at the spring and was agitating the sediment at the bottom. They fixed the break, flushed the lines of sediment, and put a drain in the holding tank to remove the rest of the sediment. They think the agitated accumulated sediment may have been causing the higher turbidity. They are also going to have a contractor go out to clean up the cemented gravel that is allowing more sediment into the spring pipe. The gravel used to be cleaner and he believes used to settle the sediment more. They also changed from a 1 micron "nominal" cartridge filter to a 1 micron "absolute" cartridge filter. Long term plans are to have a contractor out to determine how to construct the spring so that it is only groundwater. A Tier 2 public notice will be issued and a copy sent to me. ACTION NEEDED: Provide copy of Tier 2 public notice to me.


More information for this water system: SDWIS ID 3184
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login