OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 93461
PWS Name: BREITENBUSH HOT SPRINGS
 
Who Was Contacted and Phone: sdwis
Contact Date: 12/30/2011
Contacted By: BAIRD, GREGG (REGION 1)
Contact Method/Location: Office
 
Assistance Type: OTHER REGULATORY - EMERGENCY RESPONSE/OERS
Reasons: SWTR
N/A
 
Details: SUMMARY: OERS: Turbidity exceedance DETAILS: [At 1429 hrs friday 12/30/11] Breitenbush Hot Springs [called OERS and ] reported 5.6 NTU at the "back up water system" (?) near Detroit [occurred at 2030 hrs thursday 12/29/11]. At 2110 Breitenbush shut down potable water sources and isolated the system. Then they doused the reservoir with 161 Milliliters of chlorine. At 2200hrs flushed the system and re tested. Test came back PH 6.9 temp 9.7 degrees C residual chlorine 1.5, reservoir is at 10,040 gallons. 2230hrs last night the system was turned back on. At 1300 today the highest NTU was 4.3 NTU the reservoir chlorine 1.0 temperature 9 degrees C PH 6.8. The water system called OERS and OERS notified the DWP today at 3:25 pm-- the water system did not notify the DWP directly. I called the DRC Dean Terry and the system contact, Gwen Healy, and left messages for them to call me. It sounds like they caught it before it went out to distribution, but without talking to them, Im not sure how long the high NTU event was going on before they caught it. Presumably they will call OERs this weekend if the NTU goes over 5 again. ACTION NEEDED: Need to talk to system


More information for this water system: SDWIS ID 3179
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  Corrosion Control (LCR)  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Something missing? The new Chemical Results page replaces many pages, including arsenic and nitrate.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login