OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 94866
PWS Name: TOWNSEND FARMS FAIRVIEW
 
Who Was Contacted and Phone: Raed Mardina (971) 563-6838
Contact Date: 02/13/2012
Contacted By: WIDDICOMBE, KENT (DEPT OF AGRICULTURE)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: N/A
N/A
 
Details: SUMMARY: Public notice DETAILS: I received a call from James Nusrala regarding the 1/30/12 Ethylene Dibromide (EDB) results of 0.00012mg/L which is twice the MCL of .00005mg/L. The Drinking Water Rules will require the posting of a Tier 2 notice by February 15th to inform all users of the current exposure to EDB beyond the MCL. The Tier 2 Notice must have a copy sent to the Drinking Water Program (DWP) within 10 days of issuing the notice. The notice will need to be posted until all major changes have gone through plan review, been approved and installed. Please review the notice template, post it by February 15 then sending a copy to the DWP. A written Corrective Action Plan to return the system to compliance will need to be sent to the Dept of Agriculture by May 1, 2012 at the latest. I appreciate your cooperation in posting the notice e to maintain the current level of compliance. ACTION NEEDED: Post public notice at all drinking water access sites, listing the exceedence values for EDB, health issuers and the time frames regarding the sample results by February 15, 2012
 
Associated Alerts: CHEM5277 - 02/10/2012 - ETHYLENE DIBROMIDE



More information for this water system: SDWIS ID 2341
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login