Contact Date: 05/19/2009
Contacted By: HOFELD, EVAN (REGION 1)
Contact Method/Location: Office
 
Assistance Type: OTHER REGULATORY - REGULATORY ASSISTANCE
Reasons: Disinfection Byproducts
Operations
 
Details: SUMMARY: Questions about DBP Stage 2 DETAILS: Gary McLauchlin called about questions regarding reporting requirements for IDSE monitoring. I directed him to Wendy Marshall (EPA) who stated that when Stage 2 compliance monitoring begins, compliance will be based on a locational running annual average (LRAA) after collecting four quarters of samples. If the HAA5 (or TTHM) LRAA is greater than 0.060 ppm, public notification would be required. Earlier notification may be required if the LRAA exceeds the MCL based on fewer than four quarters regardless of the monitoring results of subsequent quarters (e.g. one results more than 4x the MCL will not be be offset by 3 subseqent non-detect results). IDSE standard monitoring sites are not compliance monitoring sites, so public notification is not required now or after the four quarterly samples are collected. However, under the CCR regulations individual sample results for the IDSE are to be included when reporting the range of TTHM and HAA5 results in the annual CCR. So, whatever the highest HAA5 (or TTHM) result you find during 2009, whether it is at your Stage 1 site or at one of the IDSE sites, that result must be reported in the 2009 CCR. ACTION NEEDED: Include IDSE results when determining the range of TTHM and HAA5 results for reporting in the annual CCR.


More information for this water system: SDWIS ID 3873
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login