OR41
PWS ID: 95283 ---- D&L MARKET& PRODUCE ---- INACTIVE
Chemical Results

Table is loading - please wait...
More Information
How to use this data table
  • Filter: Use the Select Analytes panel below to filter for specific analytes or groups. Note that only analytes for which there are data are listed. Use the dropdown menus in column headers and the Sample Dates box to filter results. Use the Search box to search across all columns. For example, you can enter a specific sample ID, analyte, or any other search criteria into the Search box.
  • Sort: Click column headings to sort ascending or descending. Sort by multiple columns by holding the Shift key while clicking on additional column headings. The arrow in the column heading will show in blue if the results are currently being sorted by that column.
  • Columns: Use the Columns button to select which columns to display in the table, including additional columns not shown in the default display. Drag column headings to rearrange their order.
  • DBPs & TOC: Use the DBPs & TOC button to filter the results for DBPs, TOC, and alkalinity. Columns and sort order will automatically adjust to help review the data.
  • Download: Use the Download button to export data to an Excel or CSV file. Only filtered results will be downloaded.
  • Reset: Click the Reset button to restore default settings.
Results not included & related pages
Abbreviations
  • Analyte Groups:  ARS = Arsenic, IOC = Inorganic Chemicals, LCR = Lead & Copper Rule, NO2 = Nitrite, NO3 = Nitrate
  • Analyte Levels:  MCL = Maximum contaminant level, ACL = Action level. Analyte level exceedances are indicated with bold red text.
  • Detection and Reporting Limits:  MDL = Federal minimum detection limit, MRL = Lab reporting level, ND = Not detected at the MDL or MRL.
Select Analytes

Sample Dates
From
to
Or select year:
Facility ID Facility Name Sample Point ID Sample Location Source Type Analyte Group Analyte Code Analyte Name
Use the "Select Analytes" panel above to filter.
Sample
Date
Result Units Analyte
Level
Type
Current
Analyte
Level
Analyte
Level
Units
Limit Limit
Type
Received
Date
Sample ID Comments Lab ID Lab Name Analysis Method Method Name TINWSF
ISN
TSASAMPL
ISN
TSASAR
ISN
SelectYear SelectAnalyte SelectResult SelectFacilityID SelectFacilityName SelectSamplePointID SelectSampleLocation SelectSourceType SelectLabID SelectLabName SelectMethod SelectMethodName FilterSampleDate
EP-A EP FOR WELL 1 Finished IOC 1074 ANTIMONY, TOTAL 12/11/2007 ND MCL 0.006 MG/L 0.002 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 200.9 ATOMIC ABSORPTION, PLATFORM 21927 485967 6989622007 IOC-1074 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 200.9 ATOMIC ABSORPTION, PLATFORM 2007-12-11
EP-A EP FOR WELL 1 Finished ARS 1005 ARSENIC 12/11/2007 ND MCL 0.010 MG/L 0.002 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 21927 485967 6989632007 ARS-1005 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1010 BARIUM 12/11/2007 ND MCL 2 MG/L 0.1 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 21927 485967 6989642007 IOC-1010 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1075 BERYLLIUM, TOTAL 12/11/2007 ND MCL 0.004 MG/L 0.0002 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 21927 485967 6989652007 IOC-1075 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1015 CADMIUM 12/11/2007 ND MCL 0.005 MG/L 0.002 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 21927 485967 6989662007 IOC-1015 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1020 CHROMIUM 12/11/2007 ND MCL 0.1 MG/L 0.01 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 21927 485967 6989672007 IOC-1020 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1024 CYANIDE 12/11/2007 0.0036 MG/L MCL 0.2 MG/L 0 MDL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 335.4 SPECTROPHOTOMETRIC SEMI-AUTOMATED 21927 485967 6989682007 IOC-1024 D EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 335.4 SPECTROPHOTOMETRIC SEMI-AUTOMATED 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1025 FLUORIDE 12/11/2007 ND MCL 4.0 MG/L 0.2 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 21927 485967 6989692007 IOC-1025 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 2007-12-11
EP-A EP FOR WELL 1 Finished LCR 1030 LEAD 12/11/2007 ND ACL 0.015 MG/L 0.002 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 21927 485967 6989702007 LCR-1030 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1035 MERCURY 12/11/2007 ND MCL 0.002 MG/L 0.001 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3112B MANUAL COLD VAPOR TECHNIQUE 21927 485967 6989712007 IOC-1035 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3112B MANUAL COLD VAPOR TECHNIQUE 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1036 NICKEL 12/11/2007 ND 0.01 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 21927 485967 6989722007 IOC-1036 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 2007-12-11
EP-A EP FOR WELL 1 Finished NO3 1040 NITRATE 12/11/2007 ND MCL 10 MG/L 0.2 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 21927 485967 6989732007 NO3-1040 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 2007-12-11
EP-A EP FOR WELL 1 Finished NO2 1041 NITRITE 12/11/2007 ND MCL 1 MG/L 0.2 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 21927 485967 6989742007 NO2-1041 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1045 SELENIUM 12/11/2007 ND MCL 0.05 MG/L 0.005 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 21927 485967 6989752007 IOC-1045 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3113B ATOMIC ABSORPTION, FURNACE 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1052 SODIUM 12/11/2007 8.9 MG/L ACL 20 MG/L 20 MDL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 3111B ATOMIC ABSORPTION DIRECT ASPIRATION 21927 485967 6989762007 IOC-1052 D EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 3111B ATOMIC ABSORPTION DIRECT ASPIRATION 2007-12-11
EP-A EP FOR WELL 1 Finished IOC 1085 THALLIUM, TOTAL 12/11/2007 ND MCL 0.002 MG/L 0.001 MRL 1/10/2008 20071211016 OR100039 WATERLAB CORPORATION 200.9 ATOMIC ABSORPTION, PLATFORM 21927 485967 6989772007 IOC-1085 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 200.9 ATOMIC ABSORPTION, PLATFORM 2007-12-11
EP-A EP FOR WELL 1 Finished NO3 1040 NITRATE 8/24/2007 ND MG/L MCL 10 MG/L 0.2 MRL 12/14/2007 20070824128 OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 21927 485100 6959172007 NO3-1040 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 2007-08-24
EP-A EP FOR WELL 1 Finished NO3 1040 NITRATE 8/24/2007 ND MG/L MCL 10 MG/L 0.2 MRL 9/21/2007 20070824028-I OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 21927 465627 6648812007 NO3-1040 N EP-A EP FOR WELL 1 Finished OR100039 WATERLAB CORPORATION 300.0 ION CHROMATOGRAPHY 2007-08-24



More information for this water system: SDWIS ID 4913
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login