PWS ID: 94935 ---- ODFW FALL RIVER FISH HATCHERY
Archived Chemical Results

Table is loading - please wait...
Pre-2002 data

More Information
How to use this data table
  • Filter: Use the Select Analytes panel below to filter for specific analytes or groups. Note that only analytes for which there are data are listed. Use the dropdown menus in column headers and the Sample Dates box to filter results. Use the Search box to search across all columns. For example, you can enter a specific sample ID, analyte, or any other search criteria into the Search box.
  • Sort: Click column headings to sort ascending or descending. Sort by multiple columns by holding the Shift key while clicking on additional column headings. The arrow in the column heading will show in blue if the results are currently being sorted by that column.
  • Columns: Use the Columns button to select which columns to display in the table, including additional columns not shown in the default display. Drag column headings to rearrange their order.
  • Download: Use the Download button to export data to an Excel or CSV file. Only filtered results will be downloaded.
  • Reset: Click the Reset button to restore default settings.
Abbreviations
  • Analyte Groups:  ARS = Arsenic, CEC = Contaminants of Emerging Concern, IOC = Inorganic Chemicals, LCR = Lead & Copper Rule, NO2 = Nitrite, NO3 = Nitrate, VOC = Volatile Organic Chemicals, WQ = Water Quality, XOC = Other Organic Chemicals
  • Analyte Levels:  MCL = Maximum contaminant level, ACL = Action level. Analyte level exceedances are indicated with bold red text.
  • ND = Not detected at or above the detection level.
Select Analytes

Sample Dates
From
to
Or select year:
Facility ID Facility Name Source Type Analyte Group Analyte Code Analyte Name
Use the "Select Analytes" panel above to filter.
Sample
Date
Result Analyte
Level
Type
Current
Analyte
Level
Analyte
Level
Units
Detection
Limit
Received
Date
Sample ID Lab ID Lab Name Analysis Method Method Name SelectYear SelectAnalyte SelectResult SelectFacilityID SelectFacilityName SelectSourceType SelectLabID SelectLabName SelectMethod SelectMethodName FilterSampleDate
AA WELL Raw IOC 1015 CADMIUM 7/8/1994 ND MCL 0.005 MG/L 0.0009 11/29/1995 2934-1 1 Century Testing Laboratories 213.2 ATOMIC ABSORPTION, FURNACE 1994 IOC-1015 N AA WELL Raw 1 Century Testing Laboratories 213.2 ATOMIC ABSORPTION, FURNACE 1994-07-08
AA WELL Raw IOC 1020 CHROMIUM 7/8/1994 ND MCL 0.1 MG/L 0.0003 11/29/1995 2934-1 1 Century Testing Laboratories 218.2 ATOMIC ABSORPTION, FURNACE 1994 IOC-1020 N AA WELL Raw 1 Century Testing Laboratories 218.2 ATOMIC ABSORPTION, FURNACE 1994-07-08
AA WELL Raw IOC 1036 NICKEL 7/8/1994 ND 0.009 11/29/1995 2934-1 1 Century Testing Laboratories 249.2 ATOMIC ABSORPTION, FURNACE 1994 IOC-1036 N AA WELL Raw 1 Century Testing Laboratories 249.2 ATOMIC ABSORPTION, FURNACE 1994-07-08
AA WELL Raw IOC 1045 SELENIUM 7/8/1994 ND MCL 0.05 MG/L 0.0025 11/29/1995 2934-1 1 Century Testing Laboratories 270.2 ATOMIC ABSORPTION, FURNACE 1994 IOC-1045 N AA WELL Raw 1 Century Testing Laboratories 270.2 ATOMIC ABSORPTION, FURNACE 1994-07-08
AA WELL Raw IOC 1085 THALLIUM, TOTAL 7/8/1994 ND MCL 0.002 MG/L 0.001 11/29/1995 2934-1 1 Century Testing Laboratories 279.2 ATOMIC ABSORPTION, FURNACE 1994 IOC-1085 N AA WELL Raw 1 Century Testing Laboratories 279.2 ATOMIC ABSORPTION, FURNACE 1994-07-08
AA WELL Raw NO3 1040 NITRATE 7/8/1994 0.06 MCL 10 MG/L 0.01 11/29/1995 2934-1 1 Century Testing Laboratories 353.2 CADMIUM REDUCTION, AUTOMATED 1994 NO3-1040 D AA WELL Raw 1 Century Testing Laboratories 353.2 CADMIUM REDUCTION, AUTOMATED 1994-07-08
AA WELL Raw NO2 1041 NITRITE 7/8/1994 ND MCL 1 MG/L 0.01 11/29/1995 2934-1 1 Century Testing Laboratories 353.3 CADMIUM REDUCTION, MANUAL 1994 NO2-1041 N AA WELL Raw 1 Century Testing Laboratories 353.3 CADMIUM REDUCTION, MANUAL 1994-07-08
AA WELL Raw NO3 1040 NITRATE 9/10/1996 0.06 MCL 10 MG/L 0.01 9/18/1996 960910AIAA 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1996 NO3-1040 D AA WELL Raw 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1996-09-10
AA WELL Raw NO3 1040 NITRATE 4/8/1997 0.06 MCL 10 MG/L 0.01 4/22/1997 970408AHAA 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1997 NO3-1040 D AA WELL Raw 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1997-04-08
AA WELL Raw NO3 1040 NITRATE 4/8/1998 0.07 MCL 10 MG/L 0.01 4/15/1998 980408AZAA 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1998 NO3-1040 D AA WELL Raw 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1998-04-08
AA WELL Raw WQ 1925 PH 7/8/1994 7.28 MCL 8.5 PH 0 11/29/1995 2934-1 1 Century Testing Laboratories 150.1 ELECTROMETRIC-INDIVIDUAL MEASUREMENT 1994 WQ-1925 D AA WELL Raw 1 Century Testing Laboratories 150.1 ELECTROMETRIC-INDIVIDUAL MEASUREMENT 1994-07-08
AA WELL Raw IOC 1035 MERCURY 7/8/1994 ND MCL 0.002 MG/L 0.0002 11/29/1995 2934-1 1 Century Testing Laboratories 245.1 MANUAL COLD VAPOR TECHNIQUE 1994 IOC-1035 N AA WELL Raw 1 Century Testing Laboratories 245.1 MANUAL COLD VAPOR TECHNIQUE 1994-07-08
AA WELL Raw IOC 1024 CYANIDE 7/8/1994 ND MCL 0.2 MG/L 0.003 11/29/1995 2934-1 1 Century Testing Laboratories 335.2 SPECTROPHOTOMETRIC, MANUAL 1994 IOC-1024 N AA WELL Raw 1 Century Testing Laboratories 335.2 SPECTROPHOTOMETRIC, MANUAL 1994-07-08
AA WELL Raw IOC 1055 SULFATE 7/8/1994 ND MCL 250 MG/L 0.025 11/29/1995 2934-1 1 Century Testing Laboratories 375.4 TURBIDIMETRIC 1994 IOC-1055 N AA WELL Raw 1 Century Testing Laboratories 375.4 TURBIDIMETRIC 1994-07-08
AA WELL Raw OC 2408 DIBROMOMETHANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2408 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2410 1,1-DICHLOROPROPENE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2410 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2412 1,3-DICHLOROPROPANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2412 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2413 1,3-DICHLOROPROPENE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2413 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2414 1,2,3-TRICHLOROPROPANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2414 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2416 2,2-DICHLOROPROPANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2416 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2990 BENZENE 7/8/1994 ND MCL 0.005 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2990 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2991 TOLUENE 7/8/1994 ND MCL 1 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2991 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2992 ETHYLBENZENE 7/8/1994 ND MCL 0.7 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2992 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2993 BROMOBENZENE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2993 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2996 STYRENE 7/8/1994 ND MCL 0.1 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2996 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2984 TRICHLOROETHYLENE 7/8/1994 ND MCL 0.005 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2984 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2985 1,1,2-TRICHLOROETHANE 7/8/1994 ND MCL 0.005 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2985 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2986 1,1,1,2-TETRACHLOROETHANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2986 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2987 TETRACHLOROETHYLENE 7/8/1994 ND MCL 0.005 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2987 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2988 1,1,2,2-TETRACHLOROETHANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2988 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2989 CHLOROBENZENE 7/8/1994 ND MCL 0.1 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2989 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2978 1,1-DICHLOROETHANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2978 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2979 TRANS-1,2-DICHLOROETHYLENE 7/8/1994 ND MCL 0.1 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2979 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2980 1,2-DICHLOROETHANE 7/8/1994 ND MCL 0.005 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2980 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2981 1,1,1-TRICHLOROETHANE 7/8/1994 ND MCL 0.2 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2981 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2982 CARBON TETRACHLORIDE 7/8/1994 ND MCL 0.005 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2982 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2983 1,2-DICHLOROPROPANE 7/8/1994 ND MCL 0.005 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2983 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2214 BROMOMETHANE 7/8/1994 ND ACL 0.1 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2214 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2216 CHLOROETHANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2216 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2378 1,2,4-TRICHLOROBENZENE 7/8/1994 ND MCL 0.07 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2378 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2380 CIS-1,2-DICHLOROETHYLENE 7/8/1994 ND MCL 0.07 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2380 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2976 VINYL CHLORIDE 7/8/1994 ND MCL 0.002 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2976 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2977 1,1-DICHLOROETHYLENE 7/8/1994 ND MCL 0.007 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2977 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2965 O-CHLOROTOLUENE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2965 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2966 P-CHLOROTOLUENE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2966 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2967 M-DICHLOROBENZENE 7/8/1994 ND ACL 0.6 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2967 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2968 O-DICHLOROBENZENE 7/8/1994 ND MCL 0.6 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2968 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2969 P-DICHLOROBENZENE 7/8/1994 ND MCL 0.07 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2969 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2210 CHLOROMETHANE 7/8/1994 ND 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2210 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2941 CHLOROFORM 7/8/1994 ND ACL 0.080 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2941 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2942 BROMOFORM 7/8/1994 ND ACL 0.080 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2942 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2943 BROMODICHLOROMETHANE 7/8/1994 ND ACL 0.080 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2943 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw OC 2944 DIBROMOCHLOROMETHANE 7/8/1994 ND ACL 0.080 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 XOC-2944 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2955 XYLENES, TOTAL 7/8/1994 ND MCL 10 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2955 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw VOC 2964 DICHLOROMETHANE 7/8/1994 ND MCL 0.005 MG/L 0.0005 11/29/1995 2934-1 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994 VOC-2964 N AA WELL Raw 1 Century Testing Laboratories 524.2 VOC, GC/MS, P&T, CAPCOLUMN 1994-07-08
AA WELL Raw IOC 1010 BARIUM 7/8/1994 ND MCL 2 MG/L 0.06 11/29/1995 2934-1 1 Century Testing Laboratories 208.1 ATOMIC ABSORPTION DIRECT ASPIRATION 1994 IOC-1010 N AA WELL Raw 1 Century Testing Laboratories 208.1 ATOMIC ABSORPTION DIRECT ASPIRATION 1994-07-08
AA WELL Raw IOC 1052 SODIUM 7/8/1994 7.648 ACL 20 MG/L 0.04 11/29/1995 2934-1 1 Century Testing Laboratories 273.1 ATOMIC ABSORPTION DIRECT ASPIRATION 1994 IOC-1052 D AA WELL Raw 1 Century Testing Laboratories 273.1 ATOMIC ABSORPTION DIRECT ASPIRATION 1994-07-08
AA WELL Raw IOC 1074 ANTIMONY, TOTAL 7/8/1994 ND MCL 0.006 MG/L 0.002 11/29/1995 2934-1 1 Century Testing Laboratories 204.2 ATOMIC ABSORPTION, FURNACE 1994 IOC-1074 N AA WELL Raw 1 Century Testing Laboratories 204.2 ATOMIC ABSORPTION, FURNACE 1994-07-08
AA WELL Raw ARS 1005 ARSENIC 7/8/1994 0.0029 MCL 0.010 MG/L 0.0021 11/29/1995 2934-1 1 Century Testing Laboratories 206.2 ATOMIC ABSORPTION, FURNACE 1994 ARS-1005 D AA WELL Raw 1 Century Testing Laboratories 206.2 ATOMIC ABSORPTION, FURNACE 1994-07-08
AA WELL Raw IOC 1075 BERYLLIUM, TOTAL 7/8/1994 ND MCL 0.004 MG/L 0.0008 11/29/1995 2934-1 1 Century Testing Laboratories 210.2 ATOMIC ABSORPTION, FURNACE 1994 IOC-1075 N AA WELL Raw 1 Century Testing Laboratories 210.2 ATOMIC ABSORPTION, FURNACE 1994-07-08
AA WELL Raw NO3 1040 NITRATE 12/2/1998 ND MCL 10 MG/L 0.1 12/10/1998 981202DOAA 11 Coffey Laboratories, Inc. 4500NO3D 1998 NO3-1040 N AA WELL Raw 11 Coffey Laboratories, Inc. 4500NO3D 1998-12-02
AA WELL Raw NO3 1040 NITRATE 6/25/2001 0.5 MCL 10 MG/L 0.1 7/5/2001 A10625AWAA 917 Coffey Labs -- Redmond 4500NO3D 2001 NO3-1040 D AA WELL Raw 917 Coffey Labs -- Redmond 4500NO3D 2001-06-25
AA WELL Raw NO3 1040 NITRATE 12/8/1999 ND MCL 10 MG/L 0.8 12/30/1999 991208CLAA 11 Coffey Laboratories, Inc. 4500NO3D 1999 NO3-1040 N AA WELL Raw 11 Coffey Laboratories, Inc. 4500NO3D 1999-12-08
AA WELL Raw NO3 1040 NITRATE 12/3/2001 1.1 MCL 10 MG/L 0.1 12/20/2001 A11203APAA 917 Coffey Labs -- Redmond 4500NO3D 2001 NO3-1040 D AA WELL Raw 917 Coffey Labs -- Redmond 4500NO3D 2001-12-03
AA WELL Raw IOC 1017 CHLORIDE 7/8/1994 ND MCL 250 MG/L 0.5 11/29/1995 2934-1 1 Century Testing Laboratories 325.3 1994 IOC-1017 N AA WELL Raw 1 Century Testing Laboratories 325.3 1994-07-08
AA WELL Raw IOC 1025 FLUORIDE 7/8/1994 0.05 MCL 4.0 MG/L 0.01 11/29/1995 2934-1 1 Century Testing Laboratories 340.2 1994 IOC-1025 D AA WELL Raw 1 Century Testing Laboratories 340.2 1994-07-08
AA WELL Raw WQ 1918 HARDNESS, CALCIUM MAGNESIUM 7/8/1994 26.9 0 11/29/1995 2934-1 1 Century Testing Laboratories 2340B 1994 WQ-1918 D AA WELL Raw 1 Century Testing Laboratories 2340B 1994-07-08
AA WELL Raw LCR 1022 COPPER, FREE 7/8/1994 0.003 ACL 1.3 MG/L 0.003 11/29/1995 2934-1 1 Century Testing Laboratories 6010 1994 LCR-1022 D AA WELL Raw 1 Century Testing Laboratories 6010 1994-07-08
AA WELL Raw IOC 1028 IRON 7/8/1994 0.202 MCL 0.3 MG/L 0.009 11/29/1995 2934-1 1 Century Testing Laboratories 6010 1994 IOC-1028 D AA WELL Raw 1 Century Testing Laboratories 6010 1994-07-08
AA WELL Raw CEC 1032 MANGANESE 7/8/1994 0.007 MCL 0.05 MG/L 0.002 11/29/1995 2934-1 1 Century Testing Laboratories 6010 1994 CEC-1032 D AA WELL Raw 1 Century Testing Laboratories 6010 1994-07-08
AA WELL Raw IOC 1095 ZINC 7/8/1994 0.356 MCL 5 MG/L 0.004 11/29/1995 2934-1 1 Century Testing Laboratories 6010 1994 IOC-1095 D AA WELL Raw 1 Century Testing Laboratories 6010 1994-07-08
AA WELL Raw WQ 1930 TDS 7/8/1994 154 MCL 500 MG/L 0.25 11/29/1995 2934-1 1 Century Testing Laboratories 160.1 1994 WQ-1930 D AA WELL Raw 1 Century Testing Laboratories 160.1 1994-07-08



More information for this water system: SDWIS ID 2948
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA  ::  DW Source Protection
New! Visit our new Drinking Water Source Protection page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List  ::  DW Source Protection

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login