OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00712
PWS Name: ROGUE RIVER, CITY OF
 
Who Was Contacted: Michael Bollweg
Contact Phone: 541-415-1117
Contact Date: 05/07/2018
Contacted By: KAZMIERCZAK, RUSSELL (DWP)
Contact Method/Location: Phone
 
Assistance Type: INCIDENT RESPONSE
Reasons: Chlorine
 
Details: Received an email from the Public Health Phone Duty Officer, Kristen Darmody, regarding a phone call from Michael Bollweg, DRC for the City of Rogue River. The DRC for the water system called to inform Drinking Water Services that they had a high residual chlorine level in the distribution system. Mr. Bollweg was called regarding the incident and he explained that they were in the process of starting up the surface water treatment plant and slug of treated water with a high concentration (5.7 mg/L) of chlorine was released into the distribution system as a result of delay between the point of measurement and CL17 chlorine meter. He indicated that the plant was immediately shut down the the distribution system between the plant and first non-plant user was flushed. The highest level measured in the blow off was 3.7 mg/L and the residual in the distribution is measuring 0.8 mg/L. Mr. Bollweg is confident that the slug of high chlorine did not make it to any customers. Mr. Bollweg was also informed that a public notice would not need to be issued unless the system exceeded the Maximum Residual Disinfectant Level (MRDL) chlorine which is 4.0 mg/L (see OAR 333-061-00310 and OAR 333-061-0036 (i).


More information for this water system: SDWIS ID 3990
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login