OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00707
PWS Name: LAWSON ACRES WATER ASSOCIATION
 
Who Was Contacted and Phone: Ray Boyd (541) 874-2095
Contact Date: 11/26/2007
Contacted By: STRASSNER, BOB (DWP)
Contact Method/Location: Field
 
Assistance Type: CIRCUIT RIDER ASSISTANCE
Reasons: N/A
N/A
 
Details: SUMMARY: Turbidity Profile DETAILS: I met with Lloyd Allen at the treatment plan to perform a Filter Turbidity Profile. The plant was operating at a flow of 20 gpm. The filter had been in operation for approximately 30 hrs. A siphon was set up just under the surface of the water intended to carry turbid water to waste during backwash. The first sample was a dip sample from the top of the filter representing settled water NTUs. A sample NTU of 1.0 or less is a measure of the plants ability to settle turbid raw water prior to filtration. The settled NTU value of the dip sample was 1.15 NTUs. Raw water is not normally sampled by the operator. I indicated the importance of both the raw and settled NTU readings for optimal plant operations. The plant filter material has recently been replaced. After backwash, the top of the media was inspected for mud ball formation. Large particulates were noted in the corners of the filter, as well of a great of material was settled on the top of the filter directly under the launderer (trough). I requested that normal backwash from this point forward should include a dislodging of the surface of the filter with a rake where the particulates accumulate. Over time this material will be wish out of the filter. The backwash is a manual operation where all parameters are controlled by the operator. Additional recommendations were to increase the flow in gpm during the backwash and continue to control the filter to waste portion of the backwash. Currently the operator allows the filter to produce filter water when the filter to waste turbidity reaches 1.0 NTU. I suggested not returning the filter to service until the NTUs were at a value of 0.30 NTU. ACTION NEEDED: Schedule the CT tracer study with operator.


More information for this water system: SDWIS ID 4113
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA  ::  DW Source Protection
New! Visit our new Drinking Water Source Protection page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List  ::  DW Source Protection

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login