Who Was Contacted and Phone: Doug LaGrou (541) 217-5310
Contact Date: 04/30/2008
Contacted By: MURPHEY, JEFFREY (DWP)
Contact Method/Location: Office
 
Assistance Type: CIRCUIT RIDER ASSISTANCE
Reasons: N/A
N/A
 
Details: SUMMARY: Equipment Assistance DETAILS: North Bayside Estates are actually two water systems, each with one active groundwater well and disinfection. One side adds liquid chlorine to the raw water and has a 1550 gallon mixing tank that also provides 30 minutes contact time. Water is then pumped from the mixing tank up to two 2500 gallon storage tanks that provide gravity supply to about 33 connections, another 3 connections are served by a booster pump. The other system drips liquid chlorine down the well casings and relies on the casing and a 500 hydro-pneumatic tank for contact time. Both sides have numerous deficiencies including chlorine residuals and both systems have had occasional positive coliform bacteria and e-coli results. I made a site visit on 4/22/08. I visited both the North side and the South side. Both systems need improvements, from this point forward I am going to look at the two systems together. I will prepare a report with recommendations for combining the two systems and providing a single point of disinfection. I will also quickly address equipment needed of the two systems remain separate. ACTION NEEDED: I will prepare a report with recommendations for combining the two systems.


More information for this water system: SDWIS ID 4117
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login