PWS Name: | PGE PROMONTORY PARK | ||
Who Was Contacted and Phone: | Tom Oulette (503) 630-8201 | ||
Contact Date: | 06/09/2010 | ||
Contacted By: | PATTEE, TOM (DWP) | ||
Contact Method/Location: | Office | ||
Assistance Type: | BOIL WATER | ||
Reasons: | Coliform N/A |
||
Details: | SUMMARY: Well Eval for E. coli DETAILS: Well construction is adequate. Although not a construction issue, the well is gravel packed outside of the casing between 21 to 73 feet below ground. Well draws water from an unconfined aquifer within a landslide deposit. Aquifer identified as landslide deposit so I assumed that the aquifer material approximates coarse sand, gravel, and boulders. The N. Fork Reservoir (Clackamas River) is within approximately 215 feet of the wellhead. ACTION NEEDED: Consider treatment. |