OHA Drinking Water Services
Contact Report Details |
|||
PWS ID: | OR41 93759 | ||
PWS Name: | PRATUM ELEMENTARY | ||
Who Was Contacted and Phone: | Pete Paradis (503) 873-5303 | ||
Contact Date: | 02/07/2013 | ||
Contacted By: | HENRY, ROBERT (DWP) | ||
Contact Method/Location: | Field | ||
Assistance Type: | CIRCUIT RIDER ASSISTANCE | ||
Reasons: | N/A N/A |
||
Details: | SUMMARY: Arsenic Treatment DETAILS: The school is a small, rural grade school in the Silver Falls School District. The school is a NT-NC system with a daily service population of about 91 persons. The well had exceeded the arsenic MCL until an adsorptive media process from Sunshine Water (using ADI G2 Media) was installed. Arsenic levels subsequently dropped to non detect levels. This method worked for about 1 year, and then the arsenic levels again climbed above the MCL. New media was then installed by Schneider Equipment.The new media did not operate as desired, so the SD attempted to install a smaller RO-based treatment system for the school. Just prior to final installation, it was discovered that the piping of the school would make a single unit installation difficult and expensive.Pete Paradis contacted HBH for assistance with this continuation of the arsenic issue.Corresponded with Mr. Paradis regarding change in plans for arsenic removal as recommended by Culligan. ACTION NEEDED: Continue to assist SD on this matter as requested. |