Who Was Contacted and Phone: Cammie Owens (541) 396-6012
Contact Date: 02/09/2016
Contacted By: PARRY, BETSY (REGION 2)
Contact Method/Location: Office
 
Assistance Type: OTHER REGULATORY - REGULATORY ASSISTANCE
Reasons: Lead or Copper
None
 
Details: SUMMARY: lead and copper monitoring requirements DETAILS: Dean Minard thought City of Coquille was doing their lead and copper monitoring as part of a combined distribution system. Although DWS had sent Coquille a letter in 2009 saying that was possible - that is, a combined distribution system for L&C sampling purposes for Coquille and its purchasing systems, the monitoring plan materials DWS requested were never received and therefore never approved. I discussed with Cammie on the phone, and followed up with an email outlining Dean Minards options for compliance: 1) Coquille & Dean Minard submit the originally requested materials (and monitoring locations), and if approved, Coquilles 20 samples would count for Dean Minard as well-- 2) Dean Minard collects its own 5 L&C samples every 3 years-- 3) Coquille collects the 5 L&C samples within the Dean Minard distribution & labels them appropriately. This email with the options was copied to Coquille and Coos County. ACTION NEEDED: Dean Minard and the City of Coquille will inform DWS which compliance route they will take. Since Dean Minard is currently out of compliance with the Lead and Copper Rule (none for 4.5 years), they need to collect samples in summer of 2016 even if Coquille is not yet due (if pursuing the combined plan). For whichever sized distribution system Dean Minard will be a part of, they must do the EPA evaluation of materials to identify the highest risk (tier) sites before collecting any samples.


More information for this water system: SDWIS ID 4990
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA  ::  DW Source Protection
New! Visit our new Drinking Water Source Protection page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List  ::  DW Source Protection

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login