OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00707
PWS Name: LAWSON ACRES WATER ASSOCIATION
 
Who Was Contacted and Phone: Ray Boyd/Lloyd Allen (541) 874-2095
Contact Date: 05/25/2007
Contacted By: STRASSNER, BOB (DWP)
Contact Method/Location: Office
 
Assistance Type: CIRCUIT RIDER ASSISTANCE
Reasons: N/A
N/A
 
Details: SUMMARY: Equipment calibration NTU meter 2100N DETAILS: Lawson Acres appeared on a list of SW region water treatment plants requiring various levels of assistance. I called Lawson Acres specifically to discuss scheduling a turbidity profile. The operator indicated that a recent episode of low power at the treatment plant required recalibration of the turbidimeter. Since the recalibration the readings have been off. They pulled out an old analog meter and have been using it for several weeks. The response from HACH was to send in the 2100N and we will take a look at it. I had to read the calibration procedure to reacquaint myself with the process before attempting a calibration. After the second run-through with no change I went back to the manual. In an obscure note just prior to the calibration procedure I found a statement that mentions the retention of previous calibration data and the need to zero the meters memory prior to calibration. A simple key stroke is required to zero the meter. The digital display reads double zero. A five point calibration was accomplished, this time by the operator. I suggested they run for a month using the instrument prior to our scheduling a visit to perform a turbidity profile. ACTION NEEDED: Schedule turbidity profile.


More information for this water system: SDWIS ID 4113
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login