OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00943
PWS Name: SUMMIT WATER ASSOCIATION
 
Who Was Contacted and Phone: lyon (541) 997-2511
Contact Date: 09/17/2007
Contacted By: LYON, CASEY (REGION 2)
Contact Method/Location: Office
 
Assistance Type: BOIL WATER
Reasons: Coliform
Operations
 
Details: SUMMARY: boil water notice DETAILS: System called 8/28/07 to report no water, loss of pressure. A Boil water notice was posted on 8/29/07 due to loss of pressure. On 9/11/07 Darrell Lockard of OAWU assisted me in a site visit, I took 5 samples and walked the entire system, looking at the spring and storage tank to try to determine why system is loosing pressure and where the coliform might be coming from. After looking at the storage tank and spring box for nearly an hour, we hypothesized that the system did not have a leak in their distribution system because the pump came on only once to pressurize the distribution system. If there were a leak in the distribution system the pump would be turning on more often. I took pictures of the tank that was very dirty with moss growing inside. The five routine samples that I took came back absent for total coliform. Judy stated that her son Shawn was turning off the pump at night and back on in the morning to avoid running out of water. This idea did not make sense to Darrel, or myself, I advised Judy to not turn off the pump any more. At this point the water system is back in compliance as long as they show consistent absent results for bacteria and keep at least 20 psi pressure at all times. ACTION NEEDED: continue to take quarterly coliform samples.


More information for this water system: SDWIS ID 46
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login