PWS Name: CHARLES TRACTS WATER COMPANY
 
Who Was Contacted and Phone: Bill Kik (541) 567-7589
Contact Date: 01/31/2008
Contacted By: BURNETT, GARY (DWP)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: VOCs
VOC
 
Details: SUMMARY: Chemical detections at Well 1. Well is now INACTIVE due to cave in. DETAILS: Chemical samples taken at EP-A in September 2007 showed trace amounts of VOCs including ethylbenzene, styrene, and toluene. Results were about 0.0005 mg/l. The well pump was replaced just prior to the sampling, and Mr. Kik feels the chemical detections are related to the pump work. Subsequently the well caved in so it is no longer used and the pump has been removed. Kik plans to rehab Well 2 in the near future and for now is relying on Well 3 (Chuck Wagon). Well 2 needs work to seal out hydrogen sulfide water. ACTION NEEDED: DWP to INACTIVATE Well 1 and EP-A. No further samples required. Owner to notify DWP when Well 2 has been repaired.


More information for this water system: SDWIS ID 3730
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login