OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 95001
PWS Name: SHADY COVE SUBWAY
 
Who Was Contacted and Phone: Cindy Glaspell (541) 878-2442
Contact Date: 03/27/2008
Contacted By: HOUGH, DANIEL (JACKSON COUNTY)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: Coliform
N/A
 
Details: SUMMARY: Three out of 4 repeat samples collected on 3/25/08 positive for Total Coliform (one for E.Coli) DETAILS: 03/27/08 - Three samples were collected at the sink approximately 30 minutes apart (two tested positive for Total Coliform). One sample was collected at the mechanics sink and tested positive for E. Coli. I spoke with Cindy. She has discontinued all fountain drinks. The Shady Cove Station and Subway continue to operate with bottled water for hand washing. There is no food prep process that involves water usage. Dishes continue to be done in a three compartment sink with sanitizer solution. The attached public notice was sent to Cindy. 03/27/08 - the system was shock chlorinated. 03/28/08 - The system was flushed. 03/31/08 - One sample was collected. 04/01/08 - The special sample tested negative for Total Coliform. I called Cindy and notified her of the results. The water can be used for all purposed at this time. ACTION NEEDED: Five temporary routine samples need to be collected in the month of April.
 
Associated Alerts: COLI5112 - 03/27/2008 - COLIFORM (TCR) , E. COLI

COLI5112 - 03/27/2008 - COLIFORM (TCR) , E. COLI



More information for this water system: SDWIS ID 4334
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login