PWS ID: OR41 00359
PWS Name: CORBETT WATER DISTRICT
 
Who Was Contacted and Phone: Jim Jans (503) 695-2284
Contact Date: 04/13/2010
Contacted By: NUSRALA, JAMES (REGION 1)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: SWTR
N/A
 
Details: SUMMARY: CTs not met on 4/11/10 DETAILS: Jim called at 11 am on 4/13 to report that Corbett did not meet CTs on 4/8/10. The chlorinator was down early 4/7 due to the pump not working. At this time the plant was shut down. The chlorine pump was fixed, and chlorine levels began to go up and the plant was turned back on later on 4/8. However the slug of water that was not chlorinated enough on 4/8, did not meet CTs on 4/8. Levels of residual around 1.5 mg/l in the system during this time. I mentioned to Jim the imortance of verifying CTs daily and contacting the DWP immediately, and gave him the OERS number for after hours/weekends. ACTION NEEDED: Jim to post tier II public notice and send a copy to DWP. Jim discussed moving chlorine residual meter from after clearwell to before to be able to detect low chlorine readings quicker. I relayed over the implications for CT determination if this change was made, to ensure that chlorine residual readings for after the reservoir are used for CT achieved thru the clearwell. I explained that this method is more protective, given chlorines dissipation as flow proceeds thru the system. DWP to continue to provide support as Corbett calculates CTs daily for compliance.
 
Associated Alerts: N/A - -



More information for this water system: SDWIS ID 3960
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login