OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00063
PWS Name: WICKIUP WATER DISTRICT
 
Who Was Contacted and Phone: Eric (503) 741-6658
Contact Date: 05/23/2011
Contacted By: BAIRD, GREGG (REGION 1)
Contact Method/Location:
 
Assistance Type: BOIL WATER
Reasons: N/A
N/A
 
Details: SUMMARY: Main break DETAILS: Eric from the system called Monday 8am 5/23/11 to report a mainbreak that occurred over the weekend. A main broke around midnight Saturday 5/21 around midnight and the system was losing 560 gpm. The break was discovered and isolated around 7pm Sunday 5/22. Most services kept positive pressure except about 30 on the main line going to the distribution storage tank (distribution storage tank and 2000 of the main line serving it both emptied). Eric is going to collect a special coliform sample today in the area where pressure was lost. Until the break was discovered, the treatment plants kept making water and exceeded flow rates so CTs were not met (from about noon to 7:30 pm Sunday). Treatment plant reservoirs were at 200,000 gal and 100,000 gal so there was some CT (hes not sure exactly because he hasnt done the calculations yet). Chlorine residuals are currently 0.71 ppm in the distribution and 0.64 ppm at the farthest service. ACTION NEEDED: I asked Eric to do 4 things: 1) Figure out what the CTs were yesterday, 2) Notify the services that lost pressure to flush their lines and boil water until the special coliform test results are back, 3) flush the water out of the system that didnt have full CTs, and 4) do a tier 2 PN for the entire system within 30 days for not meeting CTs.


More information for this water system: SDWIS ID 3875
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login