OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 94157
PWS Name: HAMLET QUICK-STOP
 
Who Was Contacted and Phone: Ludek Winkler (503) 738-0302
Contact Date: 07/26/2011
Contacted By: HOFELD, EVAN (REGION 1)
Contact Method/Location: Field
 
Assistance Type: OTHER REGULATORY - REGULATORY ASSISTANCE
Reasons: SWTR
Operations
 
Details: SUMMARY: Survey of system with Dept of Ag DETAILS: A site visit was completed on 7/26/11 by myself and James Nusrala as part of a water system survey conducted by Kent Widdicombe with the Oregon Dept of Agriculture. At the time of the visit, the Trojan UV Max Pro-15 diagnostic module indicated that the lamp was not functioning properly with a blinking red light and AO error code. Upon cleaning, the lamp slieve, this error was resolved. Upon remove and inspection of the Harmsco PP-HC-40-1 cartridge from the Harmsco HUR 40-HP housing, it was discovered that a retainer nut was missing. The significance was not known until the manufacturer was contacted the next morning - see contact report dated 7-27-11. ACTION NEEDED: System needed to maintain equipment per manufacturers recommendation and take a bacti sample with the next currier service on August 3rd. See contact report dated 7-27-11 for more follow-up actions.


More information for this water system: SDWIS ID 2198
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login