PWS Name: MYRTLE POINT, CITY OF
 
Who Was Contacted and Phone: Garrett Pallo (541) 266-8601
Contact Date: 12/08/2011
Contacted By: MACPHERSON, JAMES (REGION 2)
Contact Method/Location: Office
 
Assistance Type: SURVEY/DEFICIENCY FOLLOW-UP
Reasons: SWTR
None
 
Details: SUMMARY: Tracer Study DETAILS: Could historic conservative calculations supplant tracer study requirement? No. Tracer study can occur during one day of high use next spring/summer. Have to assume flows from parallel reservoirs would be nearly equivalent at maximum demand, so any hydrant discharge would need to be in tandem. SCADA system can be used to monitor water elevations in reservoirs IF resolution sufficient to measure change with sufficient accuracy during tracer study (versus placing temporary transducers). ACTION NEEDED: Review plan for tracer study when submitted.