OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00114
PWS Name: SUNSET ACRES WATER CO-OP INC
 
Who Was Contacted and Phone: Katy Crowne (541) 389-1543
Contact Date: 09/23/2014
Contacted By: MASON, JOHN (DESCHUTES COUNTY)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: Coliform
N/A
 
Details: SUMMARY: Alert follow up for positive repeats DETAILS: Quarterly sample positive for total coliform (not e.coli). Called and discuss resampling locations and timelines with Katy. Initial sample take to lab on Thursday 9/18. Sample results left of voicemail of Katy on Friday, but Katy and family out of town. Listened to message on Monday 9/22 and took three repeat samples-- one from raw water sample tap, one from North blow out valve and one from South blow off valve. She was unsure of where to take a 4th sample. The system is very old and delivers water from the system into individual cisterns for each residence. ACTION NEEDED: Discussed briefly that the water system may have to be batch chlorinated if triggered resamples come back positive. No need for public notice yet, but check O & M for sample flier if needed. Send out public notice within 30 days and get copy to me if required. Develop two other sampling locations within the middle of the system, one downstream north of well and one downstream south of well. This will require cutting in a sampling port on the delivery line after the water meter but before the house cistern. Plan to take 5 repeat samples for October 2014.
 
Associated Alerts: coli13304 - -



More information for this water system: SDWIS ID 4123
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login