PWS Name: HOPEWELL WATER COMPANY
 
Who Was Contacted and Phone: Gary VanDerVeen (503) 434-7439
Contact Date: 02/23/2016
Contacted By: HOFELD, EVAN (REGION 1)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: GWR
GWR
 
Details: SUMMARY: Boil water advisory rescinded 4-16-15 DETAILS: Following confirmed e-coli sampling in SRC-AA Nelson Spring on December 8, 2014, Hopewell Water Company was placed on a boil water advisory on December 11, 2014. 4-log disinfection was verified by HBH consulting engineers (the OHA SRF Technical Assistance Circuit Rider) based on a site visit conducted by HBH on 4/15/15. Based on this verification, a minimum entry point chlorine residual was established at 0.8 mg/l and the water system began compliance monitoring to demonstrate 4-log disinfection. Following a site visit conducted on April 16, 2015 to verify the spring collection system was not subject to further contamination, the boil water notice was rescinded effective April 16th, 2015. ACTION NEEDED: System to continue to meet an entry point chlorine residual of 0.8 mg/l and conduct compliance monitoring demonstrating 4-log viral inactivation.
 
Associated Alerts: COLI13697 - 12/11/2014 - COLIFORM (TCR) , E. COLI

COLI13697 - 12/11/2014 - COLIFORM (TCR) , E. COLI

COLI13697 - 12/11/2014 - COLIFORM (TCR) , E. COLI

COLI13697 - 12/11/2014 - COLIFORM (TCR) , E. COLI

COLI13697 - 12/11/2014 - COLIFORM (TCR) , E. COLI



More information for this water system: SDWIS ID 4134
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login