OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 90416
PWS Name: GEORGIA-PACIFIC, WAUNA MILL
 
Who Was Contacted and Phone: Hayley Moen (503) 455-3370
Contact Date: 02/26/2016
Contacted By: HOFELD, EVAN (REGION 1)
Contact Method/Location: Office
 
Assistance Type: OTHER REGULATORY - REGULATORY ASSISTANCE
Reasons: SWTR
SWTR
 
Details: SUMMARY: IFE turbidity trigger questions DETAILS: The monthly surface water treatment operating report for January 2016 submitted by the water system indicated that the individual filter effluent (IFE) turbidity triggers had been exceeded. I reviewed the report and contacted the water system. There was a misunderstanding regarding what the IFE turbidity triggers were on the part of the operator. I sent information and the rule citation under OAR 333-061-0040(1)(d)(C) for the IFE turbidity triggers, which indicates that for systems serving less than 10,000 people with conventional or direct filtration, the triggers are 1 and 2 NTU, not the 0.3 NTU that the operator had thought. The water system followed up with a corrected report on March 2, 2016 indicating that the turbidity triggers had not been exceeded. ACTION NEEDED: No further action needed at this time. System to report by the 10th of the following month if 2 consecutive readings taken 15 minutes apart exceed 1.0 NTU for any filter, 2 consecutive readings taken 15 minutes apart exceed 1.0 NTU at the same filter for 3 months in a row (a filter self-assessment must also be completed within 14 days of this exceedance), or if 2 consecutive readings taken 15 minutes apart exceed 2.0 NTU at the same filter for 2 months in a row (a Comprehensive Performance Evaluation (CPE) must also be completed within 60 days of this exceedance).


More information for this water system: SDWIS ID 3926
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login