OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 01449
PWS Name: MARSHLAND WATER ASSOCIATION
 
Who Was Contacted and Phone: Bob Bedell (503) 728-3144
Contact Date: 11/20/2017
Contacted By: NUSRALA, JAMES (REGION 1)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: Disinfection Byproducts
N/A
 
Details: SUMMARY: Follow up to DBP HAA5 OEL exceedance DETAILS: Marshlands November 2017 HAA5, haloacetic acid, sample was 0.0771 mg/L, greater than the 0.060 mg/L MCL. The running annual average is 0.050 mg/L, below the MCL, but the operational evaluation level (OEL) is 0.062, above the 0.060 mg/L limit. Discussed that while no violation requiring public notice or treatment addition/modification at this time, the OEL exceedance still requires a report within 90 days to DWS.Bob indicated hes keeping the chlorine levels lower than usual, 0.5 to 0.6 mg/L at 1st user, continuing with the 12 gpm recirculation system between the plant and the storage tank and flushing out in the distribution system at the end of the line. System has had to be off-line for a few days in November due to high raw water turbidity from recent rain events. Bob referenced lots of fall organic matter in the source watershed. ACTION NEEDED: DWS to send OEL report template to Marshland to review and complete within 90 days. DWS will provide circuit rider resource as well for DBP troubleshooting.
 
Associated Alerts: CHEM7767 - 11/16/2017 - TOTAL HALOACETIC ACIDS (HAA5)



More information for this water system: SDWIS ID 4016
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login