PWS ID: OR41 91207
PWS Name: PARADISE LODGE
 
Advisory Type: Boil Water
Reason: E. coli, Confirmed in Distribution
Area Affected: System-wide
Affected Populations: All
 
Begin Date: Jun 13, 2022
Date Lifted: Jun 16, 2022
 
Contacted By: DOWNS, KENT (DWP)
Who Was Contacted: William Benavente
Contact Phone: 541-218-8986
 
Details: The operator informed me that he received verbal notification from the lab that the results for two of the repeat samples collected on 6.10.22 came back E. Coli positive and TC positive. The RP sample collected at the kitchen faucet tested E. Coli. The upstream RP sample tested TC positive. The triggered sample at the well and the downstream RP sample were both negative for E. Coli and total coliform. After collecting the repeat samples the system was shocked with chlorine. Next Steps: - Bill was instructed to post a boil water notice. A template was provided via email. Bill will email me a copy of the public notice with the date posted. The boil notice will remain in place until a follow up sample can demonstrate absence of coliform contamination. - Before collection a follow up sample, the system will test the water to ensure levels of chlorine in the distribution are back to normal. for this system the normal chlorine level is cero. - System must develop a coliform sampling plan. A template was provided via email. Bill will email me a copy of the plan for revision and approval. - A level two coliform investigation will be coordinated with Bill.

Lifted 06/16/2022:  The system collected two special samples on 06.14.22. The test results for both samples showed absence of coliform contamination. The boil water was lifted on 06.16.2022. The system will continue with their routine coliform sampling schedule to ensure the issue is resolved. Next step: Complete a level 2 coliform investigation.

Associated Alerts: COLI22156 - 06/08/2022 - COLIFORM (TCR)   See also: 06/19/2022

COLI22181 - 06/13/2022 - COLIFORM (TCR) , E. COLI  See also: 06/19/2022



More information for this water system: SDWIS ID 3141
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login