OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 05581
PWS Name: WEISS ESTATES WATER SYSTEM
 
Who Was Contacted: Corinne Clifton
Contact Phone: 541-347-1135
Contact Date: 04/13/2023
Contacted By: CIVIL WEST ENGINEERS, INC (DWP)
Contact Method/Location: Field
 
Assistance Type: CIRCUIT RIDER ASSISTANCE
 
Details: Background/Problem Identification:

Kent Downs with OHA reached out to the circuit rider indicating that the Weiss Estates Water System needed help with sampling for WQPs (Water Quality Parameters).

Assistance Provided:

The circuit rider researched the issues with the existing WQPs sampled by C. Clifton and found that there were no pH or temperature readings taken at the time of the WQP sampling. Further one of the samples came back with non-detection for the following parameters: calcium, alkalinity, and conductivity. This is highly unusual and could only happen if the water had been deionized or if there was a mistake at the laboratory. The circuit rider discussed the issue with both OHA and C. Clifton and believes that there must have been some error at the test lab. C. Clifton confirmed that there is no filtration equipment at her house that could have been the cause of the non-detects. The circuit rider discussed the sampling procedure for WQPs with C. Clifton at length and C. Clifton confirmed that she would be able to pull the samples again and take pH and temperature readings at the sample locations at the time of sampling.

Follow-Up Actions Needed:

The circuit rider is available to assist further as needed.

Technical Reports to be Prepared and Expected Timeframe:

N/A


More information for this water system: SDWIS ID 3923
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login