OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00744
PWS Name: KEIZER, CITY OF
 
Who Was Contacted and Phone: Pat Taylor (503) 856-3560
Contact Date: 06/24/2015
Contacted By: BAIRD, GREGG (REGION 1)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: Coliform
N/A
 
Details: SUMMARY: Two routine positive total coliforms DETAILS: Pat notified OHA-DWS today that two routine samples collected Monday 6/22/15 came back positive for total coliform (absent for E. coli). The samples were collected from 2275 Manzanita St. NE and 408 Garland Ave. N. Three repeats (upstream, downstream, original site) for each site will be collected today, as well as triggered raw source samples from the 9 wells in operation at the time (Carlhaven East, Carlhaven West, Cherry, City Hall, Willamette, McNary, 17th, Delta, and Reitz). Pat said that theyve been doing some flushing of the system but did not know for sure if that had anything to do with the positive samples. ACTION NEEDED: Will wait for results of repeat samples (available Thursday 6/25/15) and respond accordingly. UPDATE: On 6/25/15 Keizer notified us that all repeats and triggered source samples were absent. No further action required at this time. Note: system is aware that no more than 5% of monthly samples (consisting of both routines and repeats) can be total coliform positive. There have been 3 positives this month which is allowed as long as a total of 60 samples for the month are collected.
 
Associated Alerts: COLI14263 - 06/25/2015 - COLIFORM (TCR)

COLI14263 - 06/25/2015 - COLIFORM (TCR)



More information for this water system: SDWIS ID 3787
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login