OHA Drinking Water Services
OHA Drinking Water Services
Contact Report Details

PWS ID: OR41 00657
PWS Name: PORTLAND WATER BUREAU
 
Who Was Contacted and Phone: Kathy Casson (503) 823-7447
Contact Date: 05/16/2007
Contacted By: SALIS, KARI (DWP)
Contact Method/Location: Office
 
Assistance Type: WATER QUALITY ALERT RESPONSE
Reasons: SOCs
N/A
 
Details: SUMMARY: Hexachlorocyclopentadiene detect DETAILS: I received an alert that there was a small detection of hexachlorocyclopentadiene (Hex) in April 2007. The level detected was 0.00008 ppm (8x10e-5). Kathy said that they detected a small amount (5x10e-5) in March, as well, but it was recorded in SDWIS as a ND. They decided to test quarterly anyway, hence this additional detect. Kathy said that the chemical can be a disinfection by-product, and it is an ingredient in at least 2 pesticides. These pesticides are not used in the watershed or near any vents, as far as they know. I checked the rules, and OAR 333-061-0036(3)(a)(C) Table 11 says that quarterly sampling is requried if the detect is equal to or greater than the value listed in that table. For this contaminant, that detection limit is listed as 0.0001 ppm, which is larger than the detections that the PWB found in March and April. I will verify with DMCA, but I interpret this to mean that quarterly sampling is not required. I will check with the DMCA unit to confirm with them. ACTION NEEDED: talk to DMCA, inform PWB of decision.


More information for this water system: SDWIS ID 3900
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA
Corrosion Control has moved to the Lead & Copper page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login